Chapter 9. Basic functions
z Accel/Decel pattern setting
Group LED display Parameter name
Min/Max
range
Set value Unit
F 2 [Accel pattern] 0
Linear
Function
group 1
F 3 [Decel pattern] 1
S-curve
0
H17
[S-Curve accel/decel
start side]
40 %
Function
group 2
H18
[S-Curve accel/decel
end side]
1~100
40 %
Accel/Decel pattern is settable at F2 and F3.
Linear: This is a general pattern for constant torque applications
S-curve: This curve allows the motor to accelerate and decelerate smoothly.
Appropriate applications: Elevator door, lifts
Caution :
For S-curve, the actual Accel/Decel time takes longer than the time set by user.
Run
command
Freq.
Accel time Decel time
Accel/Decel
Ref. Freq.
H17
H17 H18 H18
Accel Starting
Accel Starting
Decel Starting
Decel Ending
1/2 of Accel/Decel Ref. Freq
Freq