Safety Instructions for the Installer
A device must be provided in the electrical installation which
allows the appliance to be disconnected from the mains at all
poles with a contact opening width of at least 3 mm Suitable
isolation devices include line protecting cut-outs, fuses (screw
type fuses are to be removed from the holder), earth leakage trips
and contactors.
In respect of fire protection, this appliance corresponds to type
Y (EN 60335-2-6). Only this type of appliance may be installed
with a high cupboard or wall on one side.
• Drawers may not be fitted underneath the hob.
• The installation must guarantee shock protection.
The kitchen unit in which the appliance is fitted must satisfy the
stability requirements of DIN 68930.
For protection against moisture, all cut surfaces are to be sealed
with a suitable sealant.
On tiled work surfaces, the joints in the area where the hob sits
must be completely filled with grout.
On natural, artificial stone, or ceramic tops, the snap action
springs must be bonded in place with a suitable artificial resin or
mixed adhesive.
Ensure that the seal is correctly seated against the work surface
without any gaps. Additional silicon sealant must not be applied;
this would make removal more difficult when servicing.
• The hob must be pressed out from below when removed.
• Clean the work surface in the area of the cut-out.
• Sealing tape is mounted on the ceramic Glass initially.
Installation Instructions