LG LBNK1653QC.ANONE4 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aparelhos de ar condicionado "split system" LG LBNK1653QC.ANONE4. LG LBNK1653QC.ANONE4 Owner’s Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
ENGLISH
IMPORTANT
Please read through this manual. It contains valuable
information about your air conditioner. This manual may
help save time and money by explaining proper product
maintenance and preventing improper use.
PRECAUTIONS
Pay close attentio n to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages caused
by misuse of the product.
LG
Ceiling Duct-Type Air Conditioner
OWNER'S MANUAL
LG
P/No. : MFL37347405
LG Electronics India Pvt. Ltd.
Regd. Office : A-27, Mohan Cooperative Industrial
Estate, Mathura Road, New Delhi-110044.
www.lg.com
Vista de página 0
1 2 3 4 5 6 ... 63 64

Resumo do Conteúdo

Página 1 - OWNER'S MANUAL

ENGLISHIMPORTANTPlease read through this manual. It contains valuableinformation about your air conditioner. This manual mayhelp save t

Página 2

Operating InstructionsOperatingInstructions9Name and Function of Remote ControllerENGLISHOptional feature.*••(optional)(optional)(optional)(For number

Página 3 - TABLE OF CONTENTS

10Information of Slide Switch12341234(optional)(optional)IDU Fan Speed ProvisionCapacity36K BTU/h51K BTU/h66K BTU/h90K BTU/h102K BTU/h132K BTU/h198K B

Página 4 - Precautions

11AUTO SWINGHIZONEOperation unit Program setRoom TempMEDLOAUTOJETHeaterDefrostFilterPreheatHumidifyOut doorTimerOnSet no. TimeOff01 03 05 07 09 11 13

Página 5

12WeekProgramSET/CLRMinHourAUTO SWINGTimeHIZONEOperation unitRoom TempMEDLOAUTOJETHeaterDefrostFilterPreheatHumidifyOut doorTimerOnSet no.Off1 2 3 4OP

Página 6

13AUTO SWINGProgram setTimeHIZONEOperation unitRoom TempMEDLOAUTOJETHeaterDefrostFilterPreheatHumidifyOut doorTimerOnSet no.Off1 2 3 4OPERATIONFAN SPE

Página 7

14AUTO SWING OPERATIONFAN SPEEDProgram setSUB FUNCTIONSET TEMPRoom TempHIMEDLOFilter Out doorTimerOnSet no. TimeOff01 03 05 07 09 11 13 15 17 19 21 23

Página 8

15COOLING MODELCooling Operation Soft Dry OperationAUTO SWINGZONEOperation unit Program setRoom TempMEDLOAUTOJETHeaterDefrostFilterPreheatHumidifyOut

Página 9

COOLING MODELCooling OperationSoft Dry Operation Auto OperationAUTO SWINGZONEOperation unit Program setRoom TempMEDLOAUTOJETHeaterDefrostFilterPreheat

Página 10 - Operating Instructions

17COOLING MODELCooling OperationSoft Dry Operation Auto OperationAUTO SWINGZONEOperation unit Program setRoom TempMEDLOAUTOJETHeaterDefrostFilterPrehe

Página 11 - IDU Fan Speed Provision

18AUTO SWINGZONEOperation unit Program setRoom TempMEDLOAUTOJETHeaterDefrostFilterPreheatHumidifyOut doorTimeTimerOnSet no. TimeOff01 03 05 07 09 11 1

Página 13 - Weekly Programming

19Child Lock FunctionOperation procedureTo set the Child-Lock FunctionPress the Timer button and Minute Set button for three seconds. Then theoperatio

Página 14 - Holiday Setting

20NEO PLASMA Purification Operation (optional)Press the Start/Stop button.The unit will respond with abeep.1Open the door of the remotecontroller. Pre

Página 15 - Operation Mode

21Heating Operation (Heat Pump model only)ENGLISHPress the Start/Stop button.The unit will respond with a beep.11234Select Heat modeAUTO SWING OPERATI

Página 16 - Cooling Operation Mode

22Pressure FunctionSr.No.KEY & MODE OPERATION* Low PressureFunction(LP Operation)– When Low Pressure operates, itstops Comp as well as O/D Unitaft

Página 17 - Soft Dry Operation Mode

23Address Setup of Central ControlENGLISH

Página 18 - Auto Operation Mode

24The Room Temperature Confirmation

Página 19 - FAN Operation

25ROOM TEMP.OPERATION STOPSET TEMP. -0.5 °C)OPERATION STARTSET TEMP. +0.5 °C)INDOOR FANMore 3 minutesOUTDOOR FAN/COMP: SETTING FAN SPEED : LOW COOL OP

Página 20 - Operation procedure

26BenzeneSCOURINGCLBARGERSINNERAir outlet ventAir outlet ventAir filtersCare and maintenanceCare andmaintenanceIndoor UnitCaution: Before performing a

Página 21 - Operation unit

27Outdoor UnitThe heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If cloggedwith dirt or soot, the heat exchange

Página 22 - Select Heat mode

28CAUTIONCAUTION12When the air conditioner is not going to be used for a long time.Operation TipsHelpful informationThe air filters and your electiric

Página 23 - Error Diagnosis

F or Your RecordsR ead This ManualCAUTION2Ceiling Duct-Type Air Conditioner Owner’s ManualTABLE OF CONTENTSWrite the model and serial numbers here:Mod

Página 24

29Before you call for service...TroubleshootingTipsTroubleshooting Tips! Save time and money!NOTEWATER RESISTANT: The outdoor side of this appliance i

Página 25

8. Group Control9. Two Thermistor system31It operates maximum 16 Units by only one Wired Remote Controller,and each Unit starts sequentially to preven

Página 26 - Self-Diagnosis Function

7. Air Purging of the Connecting Pipes and the Indoor Unit30Indoor unitLiquid sideOutdoor unitOPEN CLOSEVaccum pumpGas sideClosedClosed2-way valve/3-w

Página 27 - Care and maintenance

4) Form the pipings1. Wrap the connecting portion of indoorunit with the Insulation material andsecure it with two Plastic Bands. (for theright piping

Página 28 - Outdoor Unit

3) Connecting the cable to theOutdoor Unit1. Remove the Cover control from the unitby loosening a screw.Connect the wires to the terminals onthe contr

Página 29 - Operation Tips

271) Arrange 2 power cables on the control panel.2) First, fasten the steel clamp with a screw to the inner boss of control panel.1) Connecting cables

Página 30 - Troubleshooting

CONTROL BOX WIRING DIAGRAM EBY33415409R Y B NCOMP1COMP2R Y B N18TERMINAL 262728293031LNHIC3C2C1R Y B N1 2 3 43ø POWER SUPPLY17 18 1920 21 22 8 9

Página 31 - 9. Two Thermistor system

CONTROL BOX WIRING DIAGRAM EBY33415410R Y B NCOMP1COMP2R Y B N R Y B NCOMP318TERMINAL 262728293031LNHIC3C2C1R Y B N1 2 3 43ø POWER SUPPLY17 18 1

Página 32 - Outdoor unit

OUTDOOR WIRING DIAGRAMINDOOR WIRING DIAGRAMGN/YLRDBKBLYLORREDBLACKGREEN/YELLOW BLUEYELLOWORANGEWHBRGNWHITEBROWNGREENTO OUTDOOR UNIT1(L)2(N)3 4 5 610AC

Página 33 - ENGLISHENGLISHENGLISHENGLISH

OUTDOOR WIRING DIAGRAMINDOOR WIRING DIAGRAMGN/YLRDBKBLYLORREDBLACKGREEN/YELLOW BLUEYELLOWORANGEWHBRGNWHITEBROWNGREENOUTDOORINDOOR3Ø415 V POWER SUPPLYP

Página 34

3WARNINGCAUTIONNever Do ThisAlways Do ThisWARNINGWARNINGPrecautionsSafetyPrecautionsTo prevent injury and property damage, follow these instructions.I

Página 35

5 CORE4 CORE5 CORESPECIFICATIONNORMAL CROSS-SECTIONAL AREA1.5 mm1.0 mm10 mm22215,16,17&187,8,9,10 & 11 1,2,3,4 & 5WIRE NO.To IndoorTERMINA

Página 36 - 3854A22012C

23Wiring DiagramUnit : 102K BTU/H(1 ODU - Single Piping)EBY43304433GN/YLRDBKBLYLORREDBLACKGREEN/YELLOW BLUEYELLOWORANGEWHBRGNWHITEBROWNGREENINDOOR WIR

Página 37

5 CORE4 CORE5 CORESPECIFICATIONNORMAL CROSS-SECTIONAL AREA1.5 mm1.0 mm10 mm22213,14,15 &167,8,9,10 &11 1,2,3,4 & 5 WIRE NO.OUTDOORINDOOR3Ø

Página 38 - INDOOR WIRING DIAGRAM

EBY43304432GN/YLRDBKBLYLORREDBLACKGREEN/YELLOW BLUEYELLOWORANGEWHBRGNWHITEBROWNGREENTO OUTDOORUNIT)1(L2(N)3 45 610ACN-D/PUMPBL BLDRAINPUMPCN-N CN-LIO

Página 39 - ENGLISHENGLISH

20Wiring DiagramUnit : 90K BTU/HEBY433044285 CORE4 CORE5 CORESPECIFICATIONNORMAL CROSS-SECTIONAL AREA1.5 mm1.0 mm10 mm22213,14,15 & 167,8,9,10 &am

Página 40 - Unit : 132K BTU/H

3 CORE3 CORE5 CORESPECIFICATIONNORMAL CROSS-SECTIONAL AREA1.5 mm1.0 mm3.5 mm2223,4 & 51,2 & 6 7,8,9,10 & 11 WIRE NO.OUTDOORINDOOR3Ø415 V P

Página 41

3 CORE3 CORE5 CORESPECIFICATIONNORMAL CROSS-SECTIONAL AREA1.5 mm1.0 mm3.5 mm22211, 13 & 149,10, & 121,2,3,7 & 8 WIRE NO.OUTDOOR WIRING DIA

Página 42 - Unit :102K BTU/H

1) Checking the Drainage1. Removethe Air Filter.2. Checkthe drainage.• S pray one or two glasses of water uponthe evaporator.• Ensure that water flow

Página 43

6) Pipe bendingAnnealed copper pipe with small diameter (ø6.35 or ø9.52) can be easily bent manually. Inthis case, secure large R(radius) for the bend

Página 44 - Unit : 90K BTU/H

153-1. Preparation of Piping3. Connecting Pipes to the Indoor UnitMain cause of gas leakage is defect inflaring work. Carry out correct flaring workin

Página 46 - Unit : 36K BTU/H

OutdoorIndoorControl terminal boardCordclamperCover controlA view11Main power sourceSwitch boxCircuit BreakerAControl terminal boardControl boxControl

Página 47 - 1) Checking the Drainage

13REFRIGERANT PIPINGINSTALLATION OF OUT DOOR UNITPerform the work according to the ServiceManual or Installation Guide.Select a location that satisfie

Página 48 - Water enters Plaster enters

12INSTALLATION OF REMOTE CONTROL BOXInstall the remote control boxand cord correctly.• A lthough the room temperature sensor is in the indoor unit, t

Página 49

11• For every 5 mitrs. increase in vertical length of the piping, U-Trap is to be provided.ENGLISHENGLISH

Página 50 - OUTDOOR UNIT

10l Drill the piping hole with 70mm dia, holecore drill.lPiping hole should be slightly slant to theoutdoor side.INSULATION, OTHERSInsulate the joint

Página 51

Ceiling5~8mmDrainage holeDrainage holeU-TrapBCA 70mmB 2CC 2 x SPSP = External Pressure(mmAq)Ex) External Pressure= 10mmAqA 70mmB 40mmC 20m

Página 52

8•Select and mark the position for fixingbolts.• Drill the hole for set anchor on the faceof ceiling.• Insert the set anchor and washer ontothe suspen

Página 53

2. Indoor unit installationnInstallation of UnitInstall the unit above the ceilingcorrectly.• Apply a joint-canvas between the unit andduct to absorb

Página 54 - REFRIGERANT PIPE

DimensionCapacityIndoor Unit (mm)36K BTU/H51K BTU/H66K BTU/H90K BTU/H102K BTU/H132K BTU/H132K BTU/H132K BTU/H198K BTU/H264K BTU/H118012301230156415641

Página 55 - UNIT AND DRAIN PIPING

DimensionCapacityA36K BTU/H51K BTU/H66K BTU/H198K BTU/H264K BTU/H12401291129119872110B11801230123019302050C365565485755920D57.557.557.55555E4806806008

Página 56

5ENGLISH

Página 57 - 2. Indoor unit installation

1. Selection of the best location1) Indoor unitSelect locationInstall the air conditioner in the location thatsatisfies the following conditions.• The

Página 58

31. The following should be always observed for safety• Please report to or take consent by the supply authority before connecting to the system.• Be

Página 59

1.The following should be always observed for safety... 32. Installation of Indoor, Outdoor Unit...

Página 61

CEILING DUCT TYPE AIR CONDITIONERSINSTALLATION INSTRUCTIONS• Please read this instruction sheet completely before installing the product.• When the po

Página 63

7ENGLISH

Comentários a estes Manuais

Sem comentários