Lg DLG2302W Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 124
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
Routing and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
•Use4-in.(10cm)diameterrigidorsemirigid
metal ductwork.
•Theexhaustductrunshouldbeasshortas
possible.
•Useasfewelbowjointsaspossible.
•Themaleendofeachsectionofexhaustduct
must point away from the dryer.
•Useducttapeonallductjoints.
•Insulateductworkthatrunsthroughunheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
IMPORTANT: Failure to exhaust the dryer
correctly will void the dryer's warranty.
VENTING THE DRYER (cont.)
Correct Venting
Incorrect Venting
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
Ductwork
4"
(10.2 cm)
4"
(10.2 cm)
Recommended
2
1
/2"
(6.35 cm)
Use Only for Short
Run Installations
Wall Cap Type
0
1
2
3
4
0
1
2
3
4
Number of 90° Elbows
Max. Length of 4-In. Dia.
Rigid Metal Duct
15
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 123 124

Comentários a estes Manuais

Sem comentários